4.2.2 SIP Setup
Gateway SIP support SIP(RFC3261), SDP(RFC2327), RFC2833, STUN(RFC3489), Symmetric
RTP, outbound proxy, ENUM(RFC2916),and RTP/RTCP.SIP NAT pass through Function can
support 80% NAT/Firewall that you don’t setting DMZ/Virtual server in router or Firewall.
1. Select “SIP Protocol”
2. SIP number / account (username) and Password Setting: Please fill out the SIP account
including username / password from ITSP.
(Note: support digits and character base SIP Account / username, some SIP Server use character
username to login, and a number to call number( ie. VoIPBuster) , if your server don’t support this,
number/Account are the same, please input the same username )
Number: Input SIP Number(Username), if your server support account and number
(different),input the number, else number/account are the same username.
Reg: let your sip account register SIP Server, click this option.
Account: Input SIP account(Username), if your server support account and number
(different),input the number, else number/account are the same username.
Password: Input Password that ITSP support.
Use Public Account: This allows gateway can use single SIP account for multiple ports.
User input the only one account in port one field for registering the ITSP.