Dynamix DW 4 FXO Guía de usuario Pagina 35

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 138
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 34
Dynamix DW-E
35
o Info Type: The info type to be validation
-DNIS: Called number
-ANI: Calling number
-IP: In coming IP address
-User: User ID
o Allow To: If it is met the ACL defined
o Disallow To: If it is not met the ACL
defined
CTB: Call Type Branch
o
PSTN To: Route for PSTN call
o
H.323 To: Route for H.323 call
o
SIP To: Route for SIP call
Cut Rule: Cut a system variable into different parts
o
Cut From: Cut start digit from (start from 1)
o
Cut To: Cut end digit to
o
Assign To: Store the cut result into
Disconnect: Disconnect the call