DynamixUMSNBUserManualVer1.00115
5.4.8. Restore factory default
The G.SHDSL .Bis NTU can restore all settings to the original factory settings simply by going to the setting menu, selecting the
Default item, and then press ENTER. The system will ask for a y(es) or n(o) confirmation followed by an ENTER.
The default vaules are as the following:
Interface Setup Parameter Default value
SHDSL
setup Interface
setup Shdsl Mode
setup Shdsl Annex
setup Shdsl Psd
setup Shdsl Startup Margin
setup Shdsl Pair Mode
E1 *Notes 1*
STU-R
Annex-G
SYM
0
1 Pair *Notes 2*
E1
setup E1 Channel
setup Pass Through
setup E1 Slot Number
setup E1 First Slot
setup E1 code
setup E1 AIS
setup E1 Build Outs
PCM31C
Off
31
1
HDB3
Off
120 Ohm