Dynamix IP PBX-100
64
User in PSTN side should be able to contact with Extensions
We hope the IP PBX-100 can pay as an Auto Attendant, so that the user in PSTN side can contact with
the Extensions. In this example, the FXO gateway connect with local PSTN line (82265699), we hope the
PSTN caller can dial to 82265699 then contact with Ext 101.
Step1: Set hotline function in your 384A.
• The default auto attendant number of IP PBX-100 is **999. So you should set hotline function of
Dynamix DW. When Dynamix DW got a PSTN incoming cal, it should dial to **999 directly. In
below picture, we set line1 to Iine3 hotline to **999 and we set Iine4 hotline to EXT 102.
Now, if FXO port1 got a PSTN incoming cal, it will hotline to auto attendant, and caller will hear a greeting
then dial extension number. If port4 got a PSTN incoming cal, Dynamix DW will dial to EXT102 directly.
102
ЕХТ101 EXT